Effect of periodic ventilation in a classroom on air quality and microclimate
https://doi.org/10.31660/2782-232X-2025-1-39-51
EDN: PIWUKL
Abstract
Air quality and microclimate parameters in classrooms impact student health and academic performance. Calculate the precise reduction in carbon dioxide concentration achieved through periodic ventilation is challenging. Therefore, an experimental study was conducted to evaluate the effect of ventilation on air quality and microclimate parameters during the cold season. The research object was a classroom with an area of 55.6 m2. On the first day of the study, ventilation was implemented before the start of classes and during breaks. On the second and third days, the ventilation schedule was determined by the students and lecturers. Carbon dioxide concentration, air temperature and relative humidity were measured using an air quality meter positioned in the center of the room at a height of 1.5 meters. On the first day, the air quality met the required standard for 16% of the teaching time, while it was acceptable and low for 47 and 37% of the time, respectively. The maximum carbon dioxide concentration reached 2639 ppm, and an unstable thermal environment was observed, with a maximum temperature increase of 4.7 °C over a 45-minute class period. Without control over the ventilation schedule and with the classroom door closed during classes, the duration of study time with poor air quality increased by 2.2 times, and the maximum carbon dioxide concentration was 1.3 times higher.
About the Authors
D. S. SimonovRussian Federation
Denis S. Simonov, Postgraduate, Senior Lecturer in the Department of Heat and Gas Supply and Ventilation
Yekaterinburg
A. Yu. Morozov
Russian Federation
Anton Yu. Morozov, Cand. Sci. (Engineering), Associate Professor in the Department of Heat and Gas Supply and Ventilation
Yekaterinburg
K. D. Konovalova
Russian Federation
Kristina D. Konovalova, Graduate Student in the Department of Heat and Gas Supply and Ventilation
Yekaterinburg
E. L. Miskova
Russian Federation
Elizaveta L. Miskova, Graduate Student in the Department of Heat and Gas Supply and Ventilation
Yekaterinburg
References
1. Denisikhina D. M. Numerical simulation of CO2 distribution in public buildings. Innovation & Investment. 2023;(5):368–372. (In Russ.) URL: https://www.innovazia.ru/archive/39071/.
2. Mansurov R. Sh., Mukhin A. I., Kostin V. I., Omelchenko D. A., Gavrilenko V. A., Sokolov Yu. G. The air regime of the premises of a small volume of public buildings with a non-stationary nature of work. News of Higher Educational Institutions. Construction. 2023;(9):46–57. (In Russ.) https://doi.org/10.32683/0536-1052-2023-777-9-46-57
3. Ulyasheva V. M., Ivanova Yu. V., Anshukova E.A. Numerical simulation of the microclimate in commercial premises. Plumbing. Heating. Air-conditioning. 2024;(9):64–67. (In Russ.) URL: https://www.c-o-k.ru/archive-cok?num=9&year=2024.
4. Datsyuk T. A., Grimitlin A. M., Taurit V. R., Ivanova Yu. V. Numerical simulation of spa ventilation. Plumbing. Heating. Airconditioning. 2024;(10):50–52. (In Russ.) URL: https://www.c-o-k.ru/archive-cok?num=10&year=2024.
5. Sadrizadeh S., Yao R., Yuan F., Awbi H., Bahnfleth W., Bi Ya. et al. Indoor air quality and health in schools: a critical review for developing the roadmap for the future school environment. Journal of Building Engineering. 2022;57:104908. https://doi.org/10.1016/j.jobe.2022.104908
6. Wargocki P., Wyon D. P. Providing better thermal and air quality conditions in school classrooms would be cost-effective. Building and Environment. 2013;59:581–589. https://doi.org/10.1016/j.buildenv.2012.10.007
7. Simonov D. S, Morozov A. Yu., Konovalova K. D, Miskova E. L. Review of research findings on the impact of air quality on learning and attendance. Plumbing. Heating. Air-conditioning. 2024;(10):54–56. (In Russ.) URL: https://www.c-o-k.ru/archive-cok?num=10&year=2024.
8. Andamon M. M., Rajagopalan P., Woo J. Evaluation of ventilation in Australian school classrooms using long-term indoor CO2 concentration measurements. Building and Environment. 2023;237:110313. https://doi.org/10.1016/j.buildenv.2023.110313
9. Cabovská B., Bekö G., Teli D., Ekberg L., Dalenb ck Ja. O., Wargocki P. et al. Ventilation strategies and indoor air quality in Swedish primary school classrooms. Building and Environment. 2022;226:109744. https://doi.org/10.1016/j.buildenv.2022.109744
10. Ding E., Zhang D., Hamida A., García-Sánchez C., Jonker L., De Boer A. R. et al. Ventilation and thermal conditions in secondary schools in the Netherlands: Effects of COVID-19 pandemic control and prevention measures. Building and Environment. 2023;229(4):109922. https://doi.org/10.1016/j.buildenv.2022.109922
11. Zhang D., Ding E., Bluyssen P. M. Guidance to assess ventilation performance of a classroom based on CO2 monitoring. Indoor and Built Environment. 2022;31(4):1107–1126. https://doi.org/10.1177/1420326X211058743
12. Simonov D. S, Morozov A. Yu., Zhilina T. S. Air exchange and air distribution in classrooms. Plumbing. Heating. Airconditioning. 2024;(7):62–65. (In Russ.) URL: https://www.c-o-k.ru/archive-cok?num=7&year=2024.
13. Korsavi S. S., Montazami A. Children's thermal comfort and adaptive behaviours; UK primary schools during nonheating and heating seasons. Energy and Buildings. 2020;214:109857. https://doi.org/10.1016/j.enbuild.2020.109857
14. Wargocki P., Porras-Salazar J. A., Contreras-Espinoza S. The relationship between classroom temperature and children’s performance in school. Building and Environment. 2019;157:197–204. https://doi.org/10.1016/j.buildenv.2019.04.046
15. Mohamed S., Rodrigues L., Omer S., Calautit J. Overheating and indoor air quality in primary schools in the UK. Energy and Buildings. 2021;250:111291. https://doi.org/10.1016/j.enbuild.2021.111291
16. Wargocki P., Foldbjerg P., Eriksen K. E., Videbæk L. E. Socio-economic consequences of improved indoor air quality in Danish primary schools. In: Indoor Air 2014. The 13th Conferenceof the International Sosiety of Indoor Air Quality and Climate. Hong Kong, July 7 to 12, 2014. Vol. 5. 2014. P. 953–958.
17. Kamenev P. N., Tertichnik E. I. Ventilation. Moscow: ASV; 2008. (In Russ.). URL: https://djvu.online/file/SYF0pFbiklm8F?ysclid=m88oek1oz901811982
18. Gorbatkova E. Yu., Аkhmadullina Kh. М., Ahmadullin U. Z., Zulkarnaev T. R., Husnutdinova Z. A., Manuilova G. R. Hygienic assessment of the air environment of student classrooms. Hygiene and Sanitation. 2022;101(4):453–458. (In Russ.) https://doi.org/10.47470/0016-9900-2022-101-4-453-458
19. Isaeva G. Sh., Ziatdinov V. B., Gabidullina S. N. The hygienic and microbiological monitoring of air in grade school. Health Care of the Russian Federation. 2016;60(2):83–88. (In Russ.) URL: https://www.elibrary.ru/item.asp?id=25717378.
Review
For citations:
Simonov D.S., Morozov A.Yu., Konovalova K.D., Miskova E.L. Effect of periodic ventilation in a classroom on air quality and microclimate. Architecture, Construction, Transport. 2025;5(1):39-51. (In Russ.) https://doi.org/10.31660/2782-232X-2025-1-39-51. EDN: PIWUKL